| Availability: | |
|---|---|
1757-SRM/A
Allen Bradley
The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module — a dedicated rack-level system redundancy module purpose‑built for Allen‑Bradley 1756 ControlLogix PLC automation control systems — establishes high-speed synchronization and runtime data mirroring between primary and standby ControlLogix controller racks, supports bumpless automatic rack switchover upon primary rack faults, ensures continuous non-stop control for critical process automation applications. Designed for petrochemical, power generation, water treatment and continuous production industries with strict zero downtime requirements, the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module integrates dedicated redundancy communication ports, status LED indicators and built‑in redundancy diagnostic logic, delivering stable data synchronization and reliable fault switching under all operating conditions.
The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module is compatible with 1756 ControlLogix chassis and matched redundant ControlLogix controllers, connects to 1756 ControlLogix chassis backplane, and operates across a standard industrial temperature range of 0 °C to +60 °C. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module carries industrial EMC compliance certification for heavy‑duty workshop environments, fully complying with UL, CE and relevant international industrial control equipment standards. Whether deployed for new high‑availability redundant control cabinet construction, critical process system renovation or spare‑part replacement for legacy ControlLogix redundant systems, the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module delivers dependable rack-level redundancy synchronization capability that ControlLogix critical automation systems demand.
Part Number | 1757-SRM/A |
Manufacturer | Allen Bradley |
System Compatibility | Allen‑Bradley 1757 |
Country of Origin | USA |
Product Condition | 100% New & Original |
Operating Temperature Range | 0 °C to +60 °C (32 °F to +158 °F) |
Lead Time | 2-3 business days after payment confirmation |
Warranty | 1 year |
Shipping Carriers | DHL, FedEx, UPS, TNT, EMS |
Contact:Cheryl Qi |
Recommended Models
The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module stands out from comparable redundancy modules in several key areas.
Rack-level full system redundancy support. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module synchronizes the whole control rack runtime data instead of only controller data, the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module supports complete rack hot standby architecture.
Bumpless rack switchover function. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module continuously mirrors all runtime data to the standby rack, the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module avoids production interruption when the primary rack fails.
Real-time redundancy link health monitoring. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module constantly checks the redundancy sync connection quality, the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module uploads fault alarms to the control program once link abnormality occurs.
Native integration with Logix redundant framework. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module redundancy parameters can be fully configured and monitored inside Studio 5000 / RSLogix 5000, the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module works with standard redundant EtherNet/IP I/O.
Intuitive LED status indication. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module has dedicated LEDs for primary, standby, sync and fault status, the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module helps maintenance technicians judge redundancy status rapidly on site.
Standard single-slot ControlLogix mechanical design. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module fits standard 1756 chassis, the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module is convenient for cabinet layout and spare part management.
Critical continuous process redundant control. Dedicated rack redundancy synchronization unit within Allen‑Bradley 1756 ControlLogix PLC systems, the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module provides high-availability control for chemical and refining production lines. Power plant auxiliary control system. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module realizes dual rack hot standby to prevent unexpected shutdown of power auxiliary equipment. Water and wastewater main process control rack. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module ensures stable and uninterrupted control for large-scale water treatment process. Legacy ControlLogix Redundant System Spare Replacement. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module is stocked as spare‑replacement unit for existing 1757-SRM/A redundant ControlLogix installations. Oil and gas skid critical control system. The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module delivers reliable rack redundancy for skid-mounted process control requiring high uptime.
The Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module holds the following international safety and compliance approvals:
• UL listed — North‑American industrial control equipment safety approval. • CE certification — European industrial control equipment safety and EMC compliance. • C‑Tick marked — EMC compliance for Australian and New Zealand markets. • Class I Division 2 certified — Suitable for installation in specified hazardous classified locations.
All modules supplied are 100% new original Allen‑Bradley parts. Every Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module unit is functionally tested before dispatch, packed in professional anti‑static packaging, and covered by a one‑year warranty from the date of delivery.
Get the Allen Bradley 1757-SRM/A with fast worldwide delivery — in‑stock units ship within 2‑3 business days of payment confirmation.
• Email: chen@htechplc.com
• WhatsApp / Phone: +86-181-5013-7565
• Shipping carriers: DHL, FedEx, UPS, TNT
Why buy from us:
• 100% new and original Allen‑Bradley 1757 series parts including the Allen‑Bradley 1757-SRM/A ControlLogix System Redundancy Module
• Every product tested before shipment
• Professional anti-static packaging
• One‑year warranty on all units
• Free online quotes and 24/7 technical support